Communications SpecialtiesPure Digital Fiberlink® 3150
User’s Manual
Broadcast quality HD/SD-SDI
transmission over one single
mode or multimode fiber.
The 3150 Series offers two
re-clocked and equalized
outputs, SMPTE 297
compliance for interfacing
with other devices, and
the signal fidelity you have
come to expect from
Pure Digital Fiberlink®!
Pure Digital Fiberlink®
3150 Series
HD/SD-SDI Transmission over one
single mode or multimode fiber.
World Headquarters
55 Cabot Court
Hauppauge, New York 11788 USA
Tel: (631) 273-0404
Fax: (631) 273-1638
info@commspecial.com
Asia
Communications Specialties Pte Ltd
100 Beach Road
#22-09 Shaw Tower
Singapore 189702
Tel: +65 6391 8790
Fax: +65 6396 0138
csiasia@commspecial.com
commspecial.com
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Contents
Contents
Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications
Model Part Number Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Transmitter Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Receiver Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operating Loss Budgets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Maximum Useable Distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Alarm Switch Settings & Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Indicator LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating Pointers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Maintenance and Repairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Certifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Accessories and Related Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Page 2
Pure Digital Fiberlink® 3150 Series User’s Manual
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Welcome | Features | Package Contents
Welcome
Thank you for purchasing Communications Specialties, Inc.’s Pure Digital Fiberlink® 3150
Series. The 3150 Series is used to transmit HD/SD-SDI with or without embedded audio
and data over a single fiber optic core. Compatible with single mode or multimode fiber,
the 3150 meets distance requirements up to 48 km. The 3150 is also compliant with SMPTE
297-2006 for seamless interoperability with other SMPTE 297-2006 devices. The system
delivers noise-free transmission that retains all of the signals’ initial parameters, regardless
of fiber optic cable attenuation. The 3150 Series also provides immunity to video
pathological signals over the entire link budget and operating temperature range.
Features
• Signal is equalized and re-clocked prior to fiber optic transmission
• Transmitter features an equalized and re-clocked SDI loop through
• Receiver features two equalized and re-clocked SDI outputs
• Designed for fiber optic interoperability with other SMPTE 297-2006 fiber optic
compliant devices up to 1.485 Gbps
• Immunity to pathological signals over entire link budget and operating
temperature range
• Compliant with SMPTE 259M-2006, 292-2006, 297-2006
• Supports transmission of SMPTE 305M-2005, 310M-2004, 344M-2000, DVB-ASI
• Supports both Single Mode and Multimode ( 62.5u & 50u) fiber types
• Supports HD/SD-SDI inputs with embedded audio and data
• 18db Optical Link Budget - 1.485 Gbps
• Wide operating temperature range: -10º C to +50º C
• Available in Box and Card versions
• Card version compatible with the Fiberlink® 6000A Rack Card Cage
• Designed and Manufactured in the USA by CSI
Package Contents
• One Pure Digital Fiberlink® 3150 or 3151
• This User’s Manual
Pure Digital Fiberlink® 3150 Series User’s Manual
Page 3
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Technical Specifications
Technical Specifications
Model Part Number Specification
Unit Type
Transmitter Box
Transmitter Rack Card
Receiver Box
Receiver Rack Card
Part Number
3150-B7L
3150-C7L
3151-B7L
3151-C7L
General Specifications
Indicators
Box Version Dimensions
Weight
Number of slots in 6000A card cage
Power
Operating Temperature
Power, HD data rate lock, SD/DVB-ASI
data rate lock, Alarm (Card version)
5.21x3.50x1.15 (in)
133x89x30 (mm)
6.9 ounces, 196 grams
1
9-24 Volts AC or DC
3150 - 3.2 Watts; 3151 - 1.8 Watts
-10ºC to +50ºC
3150 Transmitter Specifications:
Serial Video BNC Input
Number of inputs
Data Rate Range
Standards Supported
Re-clocked Data Rates
Equalization
1 BNC, 75 Ohms
19.4 Mbps to 1.485 Gbps
SMPTE 259M, 292, 297, 305M, 344M,
DVB-ASI
270 Mbps (SMPTE 259M,
DVB-ASI-270)
1.485 Gbps (SMPTE 292)
Automatic up to 200m of Belden
1694A at 1.485 Gbps and 350m
at 270 Mbps
>15dB up to 1.485 Gbps
Pure Digital Fiberlink® 3150 Series User’s Manual
Return Loss
Page 4
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Technical Specifications
Technical Specifications
3150 Transmitter Specifications (cont.)
Serial Video BNC Loop Through Output
Number of outputs
Signal Level
DC Offset
Rise/Fall Time
Overshoot
Timing Jitter
Alignment Jitter
Re-clocking
Optical Output
SMPTE 297-2006 Labeling
Connector
Wavelength
Emitter Type
Output Power
Re-clocking
L-PC-ABC-1310
LC receptacle, PC polish
1310nm
FP Laser
-3.5 dBm ±0.5 dBm
At 270 Mbps and 1.485 Gbps
1 BNC, 75 Ohms
800mv ±10%
0V ±0.5V
<270ps at 1.485 Gbps per SMPTE 292;
0.4 to 1.5ns at 270 Mbps per
SMPTE 259M
<10% of Amplitude
<0.2UI at 270Mbps, <1.0UI at 1.485
Gbps with color bar signal applied
<0.2UI at 270Mbps, <0.2UI at 1.485
Gbps with color bar signal applied
At 270 Mbps and 1.485 Gbps
3151 Receiver Specifications
Optical Input
SMPTE 297-2006 Labeling
Connector
Wavelength
Minimum Input Power
Maximum Input Power
Pure Digital Fiberlink® 3150 Series User’s Manual
PC-ABC-1310-1550
LC receptacle, PC polish
1100-1620nm
-24 dBm at 270 Mbps,
-22 dBm at 1.485 Gbps
0 dBm
Page 5
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Technical Specifications
Technical Specifications
3151 Receiver Specifications (cont.)
Serial Video BNC Outputs
Number of Outputs
Signal Level
DC Offset
Rise/Fall Time
Overshoot
Timing Jitter
Alignment Jitter
Re-clocking
2 BNC, 75 Ohms
800mv ±10%
0V ±0.5V
<270ps at 1.485 Gbps per SMPTE 292;
0.4 to 1.5ns at 270 Mbps per
SMPTE 259M
<10% of Amplitude
<0.2UI at 270Mbps, <1.0UI at 1.485
Gbps with color bar signal applied
<0.2UI at 270Mbps, <0.2UI at 1.485
Gbps with color bar signal applied
At 270 Mbps and 1.485 Gbps
3150 Transmitter - 3151 Receiver System Specifications
Operating Loss Budget
Single Mode Fiber
Multimode Fiber (62.5u)
Multimode Fiber (50u)
Maximum Useable Distance*
Single Mode Fiber
Multimode Fiber (62.5u)
Multimode Fiber (50u)
48 km at 1.485 Gbps
48 km at 270 Mbps
800 meters at 1.485 Gbps
5 km at 270 Mbps
1.2 km at 1.485 Gbps
7.5 km at 270 Mbps
18 dB at 1.485 Gbps
20 dB at 270 Mbps
18 dB at 1.485 Gbps
20 dB at 270 Mbps
18 dB at 1.485 Gbps
20 dB at 270 Mbps
*Distance specifications are approximate, based upon connecting a 3150 Transmitter to a 3150 Receiver, and are not guaranteed.
CSI cannot estimate or guarantee operating loss budgets when the 3150 Series is used with other, non-Fiberlink devices.
Operating loss budget must not be exceeded.
Page 6
Pure Digital Fiberlink® 3150 Series User’s Manual
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Installation Instructions
Installation Instructions
The Pure Digital Fiberlink® 3150 Series of fiber optic transmission systems are ready for
immediate use and do not require any special tools or equipment. However, an Optical
Power Meter, such as the Fiberlink® 6615, can be useful in determining optical loss budgets
during your systems design and maintenance.
The following instructions describe the typical installation procedure:
1)
2)
3)
4)
5)
6)
Connect the video source to the video input BNC connector on the transmitter unit.
Connect the video output cable to one of the two video output BNC connectors on
the receiver unit.
Terminate any unused BNC output connector at 75 Ohms.
Connect the fiber optic cable to the transmitter and receiver units.
Connect the Universal Power Supply to the transmitter and receiver units.
For box versions using DC power, please refer to figure 1.
When power is applied, the green POWER LED should illuminate, indicating the
presence of operating power. The HD/SD RATE LED will give an indication as described
in the Indicator LED’s and Alarm Circuitry section of this manual.
7)
The system should now be operational.
Note: The Rack Card version has an additional red LED for indicating the presence of an alarm
condition (loss of signal). Refer to Indicator LED’s and Alarm Circuitry sections of this manual.
Figure 1:
Power Connector
DC Input Polarity
(+) Positive
( - ) Negative
9-24 Volts
AC or DC
The transmitting element in the Pure Digital Fiberlink® 3150
transmitter unit contains a solid state Laser Diode located
in the optical connector. This device emits invisible infrared
electromagnetic radiation which can be harmful to human
eyes. The radiation from this optical connector, if viewed at
close range with no fiber optic cable connected to the opti-
cal connector, may be sufficient intensity to cause instanta-
neous damage to the retina of the eye. Direct viewing of this
radiation should be avoided at all times!
Pure Digital Fiberlink® 3150 Series User’s Manual
Page 7
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Alarm Switch Settings & Options
Alarm Switch Settings & Options
The Rack Card version of this product has an additional red indicator LED that illuminates
when an alarm condition exists.
The rack card unit also provides an output to drive a model 6020A Alarm Sensing Module
which provides an audible tone and activates a set of contacts for external signaling
purposes.
Alarm Switch Settings for the Transmitter Card
Switch Position
1
2
Alarm Indication
Loss of Input Video
N/A
On
Enabled
N/A
Off
Disabled
N/A
Alarm Switch Settings for the Receiver Card
Switch Position
1
2
Alarm Indication
Loss of Optical Signal
N/A
On
Enabled
N/A
Off
Disabled
N/A
Page 8
Pure Digital Fiberlink® 3150 Series User’s Manual
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Technical Specifications
Indicator LEDs
The Pure Digital Fiberlink® 3150 Series has three integral indicator LEDs that are used to
monitor the state of the unit. Card versions have an additional Alarm LED.
Transmitter LEDs
LED
Power
HD Rate
Status
On
Off
On
Off
On
On
Definition
Indicates that correct power has been applied.
Indicates no HD-SDI data rate lock
Indicates HD-SDI data rate lock at 1.485 Gbps or
1.485/1.001 Gbps
Indicates no SD-SDI or DVB-ASI data rate lock
Indicates SD-SDI or DVB-ASI data rate lock
at 270 Mbps
Loss of input video (card version only)
SD Rate
Alarm
Note: Both the HD and SD LEDs indicators are off when a non-standard signal is applied.
Receiver LEDs
LED
Power
HD Rate
Status
On
Off
On
Off
On
On
Definition
Indicates that correct power has been applied.
Indicates no HD-SDI data rate lock
Indicates HD-SDI data rate lock and re-clocked
video available on outputs
Indicates no SD-SDI or DVB-ASI data rate lock
Indicates SD-SDI or DVB-ASI data rate lock
and re-clocked video available on outputs
Loss of optical signal (card version only)
SD Rate
Alarm
Note: Both the HD and SD LEDs indicators are off when a non-standard signal is applied.
Pure Digital Fiberlink® 3150 Series User’s Manual
Page 9
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Operating Pointers | Troubleshooting
Operating Pointers
The 3150 Series is available in versions that operate with 62.5u and 50u multimode (MM)
and single mode (SM) optical fibers. Be certain that the correct size fiber is being used for
this particular transmitter/receiver combination.
Also, remember to check attenuation of the fiber optic cable. The system will only operate
properly if these specifications fall within the range of the system’s loss budget.
Troubleshooting
Multimode fiber optic cable contains an optical fiber with a light carrying “core” that is
only .0025 inches (62.5 microns) in diameter. Single mode fiber optic cable has an even
smaller “core,” only .00032 to .0004 inches (8-10 microns). This is smaller than a human hair!
Therefore, any minute particles of dirt or dust can easily block the fiber from accepting or
radiating light. To prevent this from happening, always use the provided dust caps when
ever optical connectors are exposed to air. It is also a good idea to gently clean the tip of an
optical connector with a lint-free cloth moistened with alcohol whenever dust is suspected.
The status of the LEDs should provide the first clue as to the origin of any operational
failure. If these are off, it usually means that the fiber is broken or has too much attenuation.
Next, be certain that the input and output signal connections are correct.
An optical power meter, such as the Fiberlink® 6615, a visible light source, such as the
Fiberlink® 6610, and a Three Wavelength Light Source, such as the Fiberlink® 6620, can
greatly assist and expedite troubleshooting of fiber optic transmission systems and are
recommended tools all installers should have available.
Finally, although multimode and single mode devices may look the same, they will not
operate properly together. Using the wrong device or fiber can easily add more attenuation
than specified, resulting in poor overall performance. It should be noted that some of our
fiber optic products support both single mode and multimode fiber in the same unit.
If, after reviewing the above possibilities, the system is still not operating, please contact
the Customer Service Department for further assistance. If you suspect your problem is
caused by the optics or the fiber optic cable, and you have an optical power meter, please
take the appropriate measurements prior to contacting support.
Page 10
Pure Digital Fiberlink® 3150 Series User’s Manual
 Communications Specialties - Pure Digital Fiberlink 3150 HD/SD-SDI Series Manual
Pure Digital Fiberlink® 3150 Series
Maintenance and Repairs | Certifications